Enhance patient care with our VENTILATOR AM-202. Engineered for reliability and precision, this advanced ventilator offers intuitive controls and customizable settings for optimal respiratory support. With its ergonomic design and versatile features, it ensures seamless operation in medical facilities. Trust in the AM-202 for safe and efficient ventilation management. Elevate your critical care procedures with our state-of-the-art VENTILATOR AM-202.”

Compare

AM-202 VENTILATOR

Technical Specifications:

PARAMETER SPECIFICATION
Display Mode High-definition 10.4” TFT color LCD screen
Ventilation Mode VCV, PCV, SIMV, PSV, PSV+SIMV, CPAP, PEEP, SIGH, Standby, IP, IRV
Ventilation Parameters Tidal Volume 20~1800 ml
Rate 1~120 bpm
SIMV Rate 2~20bpm
I:E 4:1~1:8
Pressure Trigger Sensitivity -1.0~2.0kPa
Flow Trigger Sensitivity 1-20L/min
PEEP 0~2.0Kpa
Pressure Range 3~60cmH2O
Pressure Support 3~60cmH2O
SIGH 1.5 times the inspiratory time (60-120 adjustable)
Inspiratory Platform 0~50%
Oxygen Concentration 48~100%
Pressure Limitation 5~60cmH2O
Pressure Slope 1~10 gear
Flow Rate Setting 1~10 gear
Expiratory Trigger Pressure -1.0~2.0kPa
Time Control 1~10s
Parameters for Ventilation Monitoring Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure – time waveform, flow rate – time waveform,PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop).
Monitoring of OxygenConcentration 48%~100%
Power AC 220V±10% 50Hz±1Hz; UPS, Storage battery
Mechanical Arms
SECURITY ALARM SYSTEM
Oxygen Concentration Alarm Upper Limit Setting Range 21%~100%
Low Limit Setting Range 10%~80%
Airway Pressure Slarm Upper Limit Setting Range 0.3~6.0 kPa
Low Limit Setting Range 0.2~5.0 kPa
Per-minute VentilationVolume Alarm Upper Limit Setting Range 3.0~30L/min
Low Limit Setting Range 1.0~10L/min
Respiratory Rate Upper Limit Setting Range 50~99bpm
Low Limit Setting Range 0~50bpm
Tidal Volume Upper Limit Setting Range 10~2000ml
Low Limit Setting Range 0~1800ml
Sustained High-pressureAlarm It will give alarm when stress have consistently been higher than 2.5kPa.
Suffocation Alarm It will give sound and light alarm if there is no tidal volume input for 15 seconds.
Power Alarm; Gas Shortage Alarm; Intubation off Alarm