AM-ARV-650 VASCULAR DOPPLER DETECTOR


Discover the precision of the Vascular Doppler Detector AM-ARV-650. This advanced device offers accurate detection of vascular sounds for comprehensive vascular assessment. Its ergonomic design ensures ease of use, while its portability allows for flexible use in various medical settings. With cutting-edge technology, the AM-ARV-650 provides superior performance and reliability. Elevate your practice with this trusted vascular Doppler detector.

Compare

AM-ARV-650 VASCULAR DOPPLER DETECTOR

Application

– Doppler Vascular Detector ARV-650 offers a full-featured ABI/vascular system for the diagnosis of peripheral arterial disease (P.A.D.) that is fast, efficient. It has 3 modalities for obtaining systolic pressures and ankle waveforms.

– Either a bi-directional Doppler probe or pulse volume recording (PVR) can be used to obtain ankle waveforms.

Features

– 5.7-inch touch screen TFT

– Obtains two pressures at each ankle site (PVR and DOPPLER)

– Automated segmental studies to customize the item

– Automatic ABI, TBI and segmental calculation

– Performs the Seated ABI on mobility impaired patients

– Bi-Directional Doppler probe

– PVR waveform modality & PPG probe to obtain toe and limb pressures

Specifications

– ABI ankle-brachial index (ABI), TBI Toe Brachial Index, ABI Seated ABI Exam, segmental exams, automatic calculation of the indices
– Control Modalities: Automatic Cuff Inflation/Deflation and hand-held controller
– Wave Modalities: bi-directional doppler, Pulse Volume Recording (PVR), (PPG) photoplethysmogra
– Doppler characteristic: Bi-directional Continuous wave (CW), Waveform amplitude accuracy: +/-10%
– Probe:8.0 MHz
– PPG characteristic: Wavelength: 940nm, Synchronous demodulation, AC paired
– PVR characteristic: Bandwidth 0.16 – 12.5 Hz, AC paired
– Pressure characteristics:

Measuring range: 0-265mmHg

Accuracy: +/-3mmHg 0-200mmHg

Pressure safety: >280mmHg automatically deflated;

>100mmHg automatically deflated after 3 minutes
– Deflated speed: Under normal circumstances 2.5mmHg/sec
– screen: 5.6 inch, TFT (640*RGB*480)
– Printer: Paper wide: 80 mm, Printing wide: 70 mm, Resolution 8 points/mm
– Data storage and transmission: store maximum of 100 patients’ data, transmit to computer via USB2.0
– Power supply: 100-240VAC, 50-60Hz
– Built-in battery: Ni-MH rechargeable batteries group, 12 V, 1800mAh

Packing Size

1PC/CTN, 42*25*32CM, 6KG/CTN