,

AM-800D MODULAR PATIENT MONITOR


Stay vigilant with our MODULAR PATIENT MONITOR AM-800D. Engineered for comprehensive monitoring, this advanced unit offers customizable modules for versatile patient care. With its intuitive interface and high-resolution display, it provides real-time data and vital signs monitoring. Trust in the AM-800D for accurate patient assessment and seamless integration into any healthcare setting. Elevate your patient care with our state-of-the-art MODULAR PATIENT MONITOR AM-800D.

Compare

AM-800D MODULAR PATIENT MONITOR

Introduction

Our modular pationt monitor can achieve modularization for function expanding with the help of integration plug-in technology, which can meet the requirement of updating and the monitors in all departments in the hospital. With various function, this machine can satisfy the convenient operation and the selection of all data of monitor in all departments in the hospitals.

Features

Integrated Plug in Modular, 12.1” colorful and clear TFT display

Standard 6 parameters and optional single plug-in parameter box

Touch screen available; able to be operated by keyboard or optional mouse

With durable trim knob and backlight silicone buttons

Simultaneously display at least 10 parameters, 13 kinds of arrhythmia analysis

ECG Waveforms of 7-lead displayed simultaneously.

Assist to judge the heart activity directly

15 kinds of drug dose calculations

Anti-electrosurgical, anti-defibrillation, suitable for monitoring critical care

Trend interface, OxyCRG interface, BigFont interface

Built-in detachable rechargeable lithium battery, battery life 4.5 hours

1000 hours trend data and trend graphs, 48 hours full waveform reviewing

Power failure data store

High capacity of information storage

NIBP dual overpressure protection

Wired/wireless connection, with system supporting 3 display screens

Supporting SD card, 4 USB interfaces

Omni-directional visible design; 3 levels of audible, visual and audio alarm; dual alarm lights for physiological and technical alarm

Technical specification

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform: 2 ch

Lead mode: 3 Leads (R, L, F or RA, LA, LL)

Lead selection: I, II, III,

Waveform: 1 ch

Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

Heart Rate

Range

-Adult: 15 ~ 300 bpm

-Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm, which great

Resolution: 1 bpm

Sensitivity: > 200 (uV P-P)

Differential Input Impedance: > 5 MΩ

CMRR

-Monitor: > 105 dB

-Operation: > 105 dB

-Diagnosis: > 85 dB

Electrode offset potential: ±300mV

Leakage Current: < 10 uA

Baseline Recovery: < 3 S after Defi.

ECG Signal Range: ±8 m V (Vp-p)

Bandwidth

-Surgery: 1 ~ 15 Hz

-Monitor: 0.5 ~ 35 Hz

-Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p), Accuracy: ±5%

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available

Review: Available

Respiration

Method: Impedance between R-F (RA-LL)

Differential Input Impedance: >2.5 MΩ

Measuring Impedance Range: 0.3~5.0Ω

Base line Impedance Range: 0 – 2.5 KΩ

Bandwidth: 0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range

-Adult: 0 ~ 120 rpm

-Neo/Ped: 0 ~ 150 rpm

Resolution: 1 rpm

Accuracy: ±2 rpm

Apnea Alarm: 10 ~ 40 S

NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,

120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and alarm range

Adult Mode

-SYS: 40 ~ 270 mmHg

-DIA: 10 ~ 215 mmHg

-MEAN: 20 ~ 235 mmHg

Pediatric Mode

-SYS: 40 ~ 200 mmHg

-DIA: 10 ~ 150 mmHg

-MEAN: 20 ~ 165 mmHg

Neonatal Mode

-SYS: 40 ~ 135 mmHg

-DIA: 10 ~ 100 mmHg

-MEAN: 20 ~ 110 mmHg

Resolution Pressure: 1mmHg

Accuracy Pressure Maximum Mean error: ±5mmHg

Maximum Standard deviation: ±8mmHg

Overpressure Protection

-Adult Mode: 297±3 mmHg

-Pediatric Mode: 240±3 mmHg

-Neonatal Mode: 147±3 mmHg

SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified

Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm

Resolution: 1bpm

Accuracy: ±2bpm

Temperature

Channel: 2

Measuring and Alarm Range: 0 ~ 50 °C

Resolution: 0.1°C

Accuracy: ±0.1°C

Actualization interval: about 1 Sec.

Average Time Constant:<10 Sec.

Configuration

Standard: ECG, RESP, NIBP, SPO2, PR, TEMP

Optional Function: Recorder, 2-IBP, VGA, ETCO2, AG (Anesthesia Gas), CO (Cardiac Output), Touch Screen, WIFI, Central Monitoring System.

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “AM-800D MODULAR PATIENT MONITOR”

There are no reviews yet.