AM-S1100 ICU VENTILATOR
Optimize patient care with the ICU VENTILATOR AM-S1100. Engineered for reliability and precision, this advanced ventilator offers intuitive controls and customizable settings for optimal respiratory support. With its ergonomic design and versatile features, it ensures seamless operation in intensive care units. Trust in the AM-S1100 for safe and efficient ventilation management. Elevate your critical care procedures with our state-of-the-art ICU VENTILATOR AM-S1100.
AM-S1100 ICU VENTILATOR
Features:
1.15” TFT LCD screen displays the Ventilation parameters, Alarming information and oscillograms, make every operation more easily.
Multiple ventilation modes, suitable for ICU, emergency department and operation room etc:(PRVC,APRV,DUOLEVEL,V-SIMV,P-SIMV,IPPV,A/C,PCV,PSV,SPONT/CPAP, SIGH, MANUAL)
2.5 oscillograms for your choice, 3 of them can be displayed on the screen at the same time.
3.Humidifier can heat and wet breathing gas,makes it comfortable for patient to breathe
4.Rapid oxygen supply, automatically offer high flow rate oxygen within two minutes.
5.Nebulization make medicine into small liquid and particle, easier and quicker for patient to breathe in.
6.High temperature resistance breathing circuit is reusable and anti-pollution.
Safety:
1.14 types of sound and visual alarm information, easier for users to do some error checking and troubleshooting.
2.Built-in oxygen concentration sensor, ensure stable precision of oxygen concentration
3.Easy to move with four casters, easy to stop with two brakes
4.Separate design of electronic circuit and gas flow rate keep safe running of ventilator.
5.Compact long life internal battery can provide emergency power, avoid risk of patient
6.Self-check before operation, eliminate system mistake
Technical Specifications:
NAME | PARAMETER |
Ventilation modes | PRVC,APRV,DUOLEVEL,V-SIMV,P-SIMV,IPPV,A/C,PCV,PSV,SPONT/CPAP, SIGH, MANUAL |
Ventilator parameter ranges | |
Tidal volume(Vt) | 0~2000mL |
Frequency (Freq) | 1min~100min |
Oxygen concentration | 21%-100% |
I/E | 4:1~1:8 |
PEEP | 0cmH2O~ 40 cmH2O |
Pressure Triggering Sensitivity (Ptr) | -20cmH2O~20cmH2O (Based on PEEP) |
Flow Triggering Sensitivity (Ftr) | 0.5L/min~30L/min |
Pressure Control | 5cmH2O~80cmH2O |
Pressure Support | 0cmH2O~80cmH2O |
SIGH | 0(off) 1/100~5/100 |
Apnea Ventilation | OFF, 5s~60s |
Pressure Limit | 20cmH2O~100cmH2O |
Monitored Parameters | |
Frequency (Freq) | 0 /min~ 100 /min |
Tidal volume(Vt) | 0 mL~ 2500 mL |
MV | 0L/min~99L/min |
Airway pressure | 0cmH2O~100cmH2O |
Dynamic Lung Compliance Testing | 1mL/cmH2O~1000mL/cmH2O |
Oxygen Concentration | 15%-100% |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | ≤11.3±0.3V |
No tidal volume | No tidal volume within 6s |
High Minute Volume alarmLow Minute Volume alarm | 5L/min-99L/min1L/min-30L/min |
High Airway pressure alarmLow Airway pressure alarm
High oxygen concentration alarm Low oxygen concentration alarm |
20cmH2O-100cmH2O0cmH2O-20cmH2O
19%-100% 18%-99% |
Continuous pressure alarm | (PEEP+1.5cmH2O) over 16s |
Suffocation warningFan error
Oxygen deficit |
5-60sShow on screen
Show on screen |
The maximum limited pressure | <12.5 kPa |
Working conditions | |
Gas source | O2,AIR |
Pressure | 280kPa-600kPa |
Voltage | 220V±22V |
Power frequency | 50Hz±1Hz |
Input power | 900VA(with air compressor)250VA(without air compressor) |
Oscillogram | |
P-T | Pressure Time |
F-T | Flow-Time |
V-T | Volume Time |
P-V Loop | Pressure-Volume Loop |
F-V Loop | Flow Volume Loop |
P-F Loop | Pressure-Flow Loop |
There are no reviews yet.