KU-F20 Feces Analyzer
Streamline fecal analysis with the Feces Analyzer KU-F20. Engineered for efficiency and accuracy, this analyzer delivers precise results for fecal sample testing. With its advanced features and user-friendly design, it ensures reliable performance in laboratory settings. Simplify your fecal analysis processes with the KU-F20 – your trusted solution for efficient and accurate feces analysis.
KU-F20 Feces Analyzer
Features
Ø Patented Rail-Type sampling method.
Ø Automated filtering negative samples, negative filter rate >80% .
Ø Patented sample collection cup uses double-chamber design with double-filtering, fully mixing and better filtering, specially
Ø design for normal and watery specimen.
Ø Patented “bullet-cartridge” design and moisture-proof card collection device,maximum 200 tests available,without manual operation.
Ø High-precision quartz-based counting chamber and imported pinch valve,Prevent pipeline blocking and cross contamination.
Ø FOB, TF, bacteriology, virology and other related cards combinable, up to 6 items can be detect in one sample.
Ø Specially design for exhaust gas treatment, improving clinical laboratory environment.
Ø Automated interpret colors and characters of the sample.
Ø Double microscopy screening; Automated recognize and locate the formed elements by AI technology, reduce review workloads.
Ø Multi-layer and multi-photo scanning , same effect as microscopic fine turning.
Ø Duplex communication; automatically detect after barcode screening.
Ø Keyu Bio quality controls available, Including Fecal form element controls, Multi-level FOB/TF controls.
Test Items
Ø Microscopic Exam: Visible Formed Elements in feces (cells, eggs, fat globules etc.) can be detected and identified;
Ø Physical Test: Physical parameters like color, character, etc. can be evaluated by automatic image captured;
Ø FOB Detection: Automatic analysis of fecal occult blood and transferrin through Colloidal gold method test parameters;
Ø Virological Test: Colloidal gold method test parameters, like rotavirus, adenovirus, coxsackie virus etc. can be evaluated automatically.
Ø Bacteriological Test: Colloidal gold method test parameters, like helicobacter pylori etc. can be evaluated automatically;
Ø Various Combinations:
Microscopy + FOB
Microscopy + FOB +TF
Microscopy +TF +HP
Microscopy +Rotavirus
Microscopy +Rotavirus+Adenovirus
Microscopy +Rotavirus+Adenovirus+Calprotectin
Working Principle
Ø Physical Test:Automated photograph and save the sample Characteristics diagram, The sample information transfer to host instrument with built-in barcode reader or
external barcode gun.
Ø Morphological Test: Automated photograph the formed elements through objective lens, sieve the nagative samples and auxiliary interpret the positive samples.
Ø Digestive Tract Occult Blood and Pathogens Detection: Automatically photographed and interpretate on various cards of FOB, virology and bacteriology by the device
vision.
Technical Specifications
PARAMETER | SPECIFICATIONS |
Test Speed | ≥ 85 Sample/hour |
Test Channel | Dual channel ,flow quartz counting chamber |
Report Unit | XX HP or XX /LP or quantitative gradient report. qualitative or semi-quantitative.result for Colloidal gold test. |
Report Format | A4 /A5 form With pictures and texts ,Result Include physical index, microscopic items and colloidal gold item. |
Microscope | High/Low power dual objective lens |
Camera | ≥ 5 million pixels. |
Microscopic Image | 6 snapshot modes, ≥ 176 vision, vision result definable |
Shooting Mode | Separate Surface and bottom layer, multi-layer scanning. Better Contrast. |
Physics Detection | Automatically identify, shoot and store sample characters. |
Formed Element Detection | Red blood cells, white blood cells, eggs etc. |
Results Interpretation | Automatically identified, negative sieving rate ≥ 80% |
Chemical Substances Detection | Automatically interpret FOB and TF in feces, FOB&TF combo test available. |
Digestive Tract Protein Test | Automatic Semi-quantitative detect and interpret for calprotectin |
Bacteriology Detection | Automatically interpretation of helicobacter pylori test results. |
Virological Detection | Automatically detect and interpret intestinal adenovirus, rotavirus and coxsackievirus |
Sample Delivery | Sealed and rail-type delivery, 50 sample available in the waiting area |
Emergency Functions | Emergency space available, Detect in time |
Colloidal Gold Test Detection | Simultaneously detect more than 6 different item with different reaction time, Independent test channel and the reaction time, shortest reaction time 3 mins ,longest more than 15 mins . |
Storage Capacity | 5 card boxes, Maximum 200 test available. |
Duplex Communication | Built-in barcode reader, LIS, HIS connection available |
FOB Controls (Automatic Detection)
Product Name | Model | Specification | Number of Testsv | Packing Specification | Purpose | |
FOB multi-level indefinite value controls
|
Level IV-II | Negative controls/bottle
Low value controls /bottle High value controls/bottle Ultra high value control/bottle |
3mL/bottle
4 Bottles/ground |
6 tests/ground
60 testes/ground |
10 groups /box | For quality control |
FOB multi-level indefinite value controls | Level III-II | Negative controls/bottle
Low value controls /bottle High value controls/bottle |
3mL/bottle
3 Bottles/ground |
6 tests/ground
60 testes/ground |
10 groups /box | |
FOB multi-level indefinite value controls | Level II-II | Negative controls/bottle
Low value controls /bottle |
3mL/bottle
2 Bottles/ground |
6 tests/ground
60 testes/ground |
10 groups /box |
TF Controls (Automatic Detection)
Product Name | Model | Specification | Number of Testsv | Packing Specification | Purpose | |
TF multi-level indefinite
value controls |
Tf-IV-II
|
Negative controls/bottle
Low value controls /bottle High value controls/bottle Ultra high value control/bottle |
3mL/bottle
4 Bottles/ground |
6 tests/ground
60 testes/ground |
10 groups /box | For quality control |
FOB multi-level indefinite value controls | Tf-III-II | Negative controls/bottle
Low value controls /bottle High value controls/bottle |
3mL/bottle
3 Bottles/ground |
6 tests/ground
60 testes/ground |
10 groups /box | |
FOB multi-level indefinite value controls | TF-II-II | Negative controls/bottle
Low value controls /bottle |
3mL/bottle
2 Bottles/ground |
6 tests/ground
60 testes/ground |
10 groups /box |
Form Element Controls (Automatic Detection)
Product Name | Model and Name | Specifications | Test No. | Purpose |
Feces Formed
Element Controls
|
QC-I:(Fertilized) Egg of ascaris
lumbricoides positive controls |
1ml/piece
1piece/box |
2T/piece
|
For quality control |
QC-II:Egg of trichinella
trichurus positive controls
|
1ml/piece
1piece/box |
2T/piece | ||
QC-III:Egg of clonorchis
sinensis positive controls
|
1ml/piece
1piece/box |
2T/piece | ||
QC-IV:Red blood cells
indefinited value controls |
(High Value controls:5ml/piece*2
Low value controls:5ml/piece*2)/box |
3T/piece
6T/box |
||
QC-V:White blood
cells positive controls |
5ml/piece
4piece/box |
3T/piece
12T/box |
There are no reviews yet.